{"id":251574,"date":"2026-04-09T07:23:54","date_gmt":"2026-04-09T07:23:54","guid":{"rendered":"https:\/\/deltacontrols.nl\/"},"modified":"2026-04-10T07:05:16","modified_gmt":"2026-04-10T07:05:16","slug":"36-900-ball-valve-repair-refurbishment-for-gas-transmission","status":"publish","type":"project","link":"https:\/\/deltacontrols.nl\/fr\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/","title":{"rendered":"R\u00e9paration et remise \u00e0 neuf d'un robinet \u00e0 tournant sph\u00e9rique 900# de 36 pouces pour le transport de gaz"},"content":{"rendered":"<p>Delta Controls fournit des services sp\u00e9cialis\u00e9s <strong>services de r\u00e9paration et de remise \u00e0 neuf des robinets \u00e0 boisseau sph\u00e9rique<\/strong> pour le secteur europ\u00e9en de l'\u00e9nergie. Nous avons achev\u00e9 la r\u00e9vision de trois <strong>Robinets \u00e0 tournant sph\u00e9rique Pibiviesse 36\u2033 900#<\/strong> op\u00e9rant dans la <strong>R\u00e9seau de transport de gaz naturel NOGAT aux Pays-Bas<\/strong>.<\/p>\n<p>Apr\u00e8s plus de deux d\u00e9cennies de fonctionnement continu dans des conditions exigeantes, les vannes ont \u00e9t\u00e9 enti\u00e8rement remises \u00e0 neuf et restaur\u00e9es en \u00e9tat de marche. <strong>de nouvelles normes de performance<\/strong>.<\/p>\n<h2>Champ d'application<\/h2>\n<p>Notre processus de r\u00e9novation comprenait<\/p>\n<ul>\n<li>D\u00e9montage complet, inspection et v\u00e9rification des dimensions<\/li>\n<li><strong>Reconditionnement des composants critiques<\/strong> utilisant l'ENP (Electroless Nickel Plating)<\/li>\n<li>Remplacement des pi\u00e8ces us\u00e9es ou non r\u00e9parables par <strong>Composants \u00e9quivalents aux OEM<\/strong><\/li>\n<li>Remontage selon les sp\u00e9cifications du fabricant d'origine<\/li>\n<\/ul>\n<h2>Essais et conformit\u00e9<\/h2>\n<p>Toutes les vannes ont \u00e9t\u00e9 test\u00e9es pour s'assurer de leur conformit\u00e9 aux normes internationales et de leur s\u00e9curit\u00e9 op\u00e9rationnelle :<\/p>\n<ul>\n<li><strong>Essai hydrostatique \u00e0 la pression de conception<\/strong><\/li>\n<li><strong>Essai de couple \u00e0 pleine pression diff\u00e9rentielle<\/strong><\/li>\n<li>V\u00e9rification conform\u00e9ment \u00e0 <strong>Exigences de l'API 6D<\/strong><\/li>\n<\/ul>\n<h2>Rev\u00eatement et protection<\/h2>\n<p>Pour garantir une durabilit\u00e9 \u00e0 long terme dans les environnements offshore et difficiles, les vannes ont \u00e9t\u00e9 recouvertes d'une couche de protection contre la corrosion. <strong>syst\u00e8me de rev\u00eatement offshore triple couche<\/strong>, L'application de ces normes est conforme aux sp\u00e9cifications du client et aux normes industrielles.<\/p>\n<h2>R\u00e9sultat<\/h2>\n<p>Les robinets \u00e0 boisseau sph\u00e9rique remis \u00e0 neuf sont d\u00e9sormais enti\u00e8rement conformes \u00e0 la norme <strong>des normes modernes de performance et de s\u00e9curit\u00e9<\/strong>, Le syst\u00e8me de gestion de l'\u00e9nergie de l'Union europ\u00e9enne est pr\u00eat \u00e0 fonctionner de mani\u00e8re fiable et \u00e0 long terme dans les infrastructures gazi\u00e8res critiques de toute l'Europe.<\/p>\n<p>&nbsp;<\/p>\n<div class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" class=\"wpa-warning wpa-image-missing-alt size-medium wp-image-251577 alignleft\" src=\"https:\/\/deltacontrols.nl\/wp-content\/uploads\/2026\/04\/001-300x225.webp\" alt=\"\" width=\"300\" height=\"225\" data-warning=\"Ontbrekende alt-tekst\" \/><\/div>\n<div class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" class=\"wpa-warning wpa-image-missing-alt size-medium wp-image-251578 alignleft\" src=\"https:\/\/deltacontrols.nl\/wp-content\/uploads\/2026\/04\/DSC01077-300x225.webp\" alt=\"\" width=\"300\" height=\"225\" data-warning=\"Ontbrekende alt-tekst\" \/><\/div>\n<div class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" class=\"wpa-warning wpa-image-missing-alt size-medium wp-image-251579 alignleft\" src=\"https:\/\/deltacontrols.nl\/wp-content\/uploads\/2026\/04\/P1140030-300x225.webp\" alt=\"\" width=\"300\" height=\"225\" data-warning=\"Ontbrekende alt-tekst\" \/><\/div>\n<div class=\"wp-block-image\"><img loading=\"lazy\" decoding=\"async\" class=\"wpa-warning wpa-image-missing-alt size-medium wp-image-251580 alignleft\" src=\"https:\/\/deltacontrols.nl\/wp-content\/uploads\/2026\/04\/PB263763-1-300x225.webp\" alt=\"\" width=\"300\" height=\"225\" data-warning=\"Ontbrekende alt-tekst\" \/><\/div>","protected":false},"excerpt":{"rendered":"<p>Delta Controls delivers specialized ball valve repair and refurbishment services for the European energy sector. We completed the overhaul of three Pibiviesse 36&#8243; 900# ball valves operating in the NOGAT natural gas transmission network in the Netherlands. After more than two decades of continuous operation in demanding conditions, the valves were fully refurbished and restored [&hellip;]<\/p>\n","protected":false},"author":6,"featured_media":251575,"template":"","meta":{"_acf_changed":false,"_et_pb_use_builder":"","_et_pb_old_content":"","_et_gb_content_width":"","footnotes":""},"project_category":[74],"project_tag":[],"class_list":["post-251574","project","type-project","status-publish","has-post-thumbnail","hentry","project_category-repair-refurbishment"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v28.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>36\u201d 900# Ball Valve Repair &amp; Refurbishment for Gas Transmission - Delta Controls<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/deltacontrols.nl\/fr\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/\" \/>\n<meta property=\"og:locale\" content=\"fr_FR\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"36\u201d 900# Ball Valve Repair &amp; Refurbishment for Gas Transmission - Delta Controls\" \/>\n<meta property=\"og:description\" content=\"Delta Controls delivers specialized ball valve repair and refurbishment services for the European energy sector. We completed the overhaul of three Pibiviesse 36&#8243; 900# ball valves operating in the NOGAT natural gas transmission network in the Netherlands. After more than two decades of continuous operation in demanding conditions, the valves were fully refurbished and restored [&hellip;]\" \/>\n<meta property=\"og:url\" content=\"https:\/\/deltacontrols.nl\/fr\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/\" \/>\n<meta property=\"og:site_name\" content=\"Delta Controls\" \/>\n<meta property=\"article:modified_time\" content=\"2026-04-10T07:05:16+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/deltacontrols.nl\/wp-content\/uploads\/2026\/04\/PB263763.webp\" \/>\n\t<meta property=\"og:image:width\" content=\"2304\" \/>\n\t<meta property=\"og:image:height\" content=\"1728\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/webp\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Dur\u00e9e de lecture estim\u00e9e\" \/>\n\t<meta name=\"twitter:data1\" content=\"2 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/deltacontrols.nl\\\/project\\\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\\\/\",\"url\":\"https:\\\/\\\/deltacontrols.nl\\\/project\\\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\\\/\",\"name\":\"36\u201d 900# Ball Valve Repair & Refurbishment for Gas Transmission - Delta Controls\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/deltacontrols.nl\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/deltacontrols.nl\\\/project\\\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/deltacontrols.nl\\\/project\\\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/deltacontrols.nl\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PB263763.webp\",\"datePublished\":\"2026-04-09T07:23:54+00:00\",\"dateModified\":\"2026-04-10T07:05:16+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/deltacontrols.nl\\\/project\\\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\\\/#breadcrumb\"},\"inLanguage\":\"fr-FR\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/deltacontrols.nl\\\/project\\\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"fr-FR\",\"@id\":\"https:\\\/\\\/deltacontrols.nl\\\/project\\\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\\\/#primaryimage\",\"url\":\"https:\\\/\\\/deltacontrols.nl\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PB263763.webp\",\"contentUrl\":\"https:\\\/\\\/deltacontrols.nl\\\/wp-content\\\/uploads\\\/2026\\\/04\\\/PB263763.webp\",\"width\":2304,\"height\":1728},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/deltacontrols.nl\\\/project\\\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/deltacontrols.nl\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Projects\",\"item\":\"https:\\\/\\\/deltacontrols.daarso.nl\\\/project\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"36\u201d 900# Ball Valve Repair &#038; Refurbishment for Gas Transmission\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/deltacontrols.nl\\\/#website\",\"url\":\"https:\\\/\\\/deltacontrols.nl\\\/\",\"name\":\"Delta Controls\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/deltacontrols.nl\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"fr-FR\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"R\u00e9paration et remise \u00e0 neuf d'un robinet \u00e0 tournant sph\u00e9rique 900# de 36 pouces pour le transport de gaz - Delta Controls","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/deltacontrols.nl\/fr\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/","og_locale":"fr_FR","og_type":"article","og_title":"36\u201d 900# Ball Valve Repair & Refurbishment for Gas Transmission - Delta Controls","og_description":"Delta Controls delivers specialized ball valve repair and refurbishment services for the European energy sector. We completed the overhaul of three Pibiviesse 36&#8243; 900# ball valves operating in the NOGAT natural gas transmission network in the Netherlands. After more than two decades of continuous operation in demanding conditions, the valves were fully refurbished and restored [&hellip;]","og_url":"https:\/\/deltacontrols.nl\/fr\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/","og_site_name":"Delta Controls","article_modified_time":"2026-04-10T07:05:16+00:00","og_image":[{"width":2304,"height":1728,"url":"https:\/\/deltacontrols.nl\/wp-content\/uploads\/2026\/04\/PB263763.webp","type":"image\/webp"}],"twitter_card":"summary_large_image","twitter_misc":{"Dur\u00e9e de lecture estim\u00e9e":"2 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/deltacontrols.nl\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/","url":"https:\/\/deltacontrols.nl\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/","name":"R\u00e9paration et remise \u00e0 neuf d'un robinet \u00e0 tournant sph\u00e9rique 900# de 36 pouces pour le transport de gaz - Delta Controls","isPartOf":{"@id":"https:\/\/deltacontrols.nl\/#website"},"primaryImageOfPage":{"@id":"https:\/\/deltacontrols.nl\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/#primaryimage"},"image":{"@id":"https:\/\/deltacontrols.nl\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/#primaryimage"},"thumbnailUrl":"https:\/\/deltacontrols.nl\/wp-content\/uploads\/2026\/04\/PB263763.webp","datePublished":"2026-04-09T07:23:54+00:00","dateModified":"2026-04-10T07:05:16+00:00","breadcrumb":{"@id":"https:\/\/deltacontrols.nl\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/#breadcrumb"},"inLanguage":"fr-FR","potentialAction":[{"@type":"ReadAction","target":["https:\/\/deltacontrols.nl\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/"]}]},{"@type":"ImageObject","inLanguage":"fr-FR","@id":"https:\/\/deltacontrols.nl\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/#primaryimage","url":"https:\/\/deltacontrols.nl\/wp-content\/uploads\/2026\/04\/PB263763.webp","contentUrl":"https:\/\/deltacontrols.nl\/wp-content\/uploads\/2026\/04\/PB263763.webp","width":2304,"height":1728},{"@type":"BreadcrumbList","@id":"https:\/\/deltacontrols.nl\/project\/36-900-ball-valve-repair-refurbishment-for-gas-transmission\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/deltacontrols.nl\/"},{"@type":"ListItem","position":2,"name":"Projects","item":"https:\/\/deltacontrols.daarso.nl\/project\/"},{"@type":"ListItem","position":3,"name":"36\u201d 900# Ball Valve Repair &#038; Refurbishment for Gas Transmission"}]},{"@type":"WebSite","@id":"https:\/\/deltacontrols.nl\/#website","url":"https:\/\/deltacontrols.nl\/","name":"Delta Controls","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/deltacontrols.nl\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"fr-FR"}]}},"_links":{"self":[{"href":"https:\/\/deltacontrols.nl\/fr\/wp-json\/wp\/v2\/project\/251574","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/deltacontrols.nl\/fr\/wp-json\/wp\/v2\/project"}],"about":[{"href":"https:\/\/deltacontrols.nl\/fr\/wp-json\/wp\/v2\/types\/project"}],"author":[{"embeddable":true,"href":"https:\/\/deltacontrols.nl\/fr\/wp-json\/wp\/v2\/users\/6"}],"version-history":[{"count":4,"href":"https:\/\/deltacontrols.nl\/fr\/wp-json\/wp\/v2\/project\/251574\/revisions"}],"predecessor-version":[{"id":251656,"href":"https:\/\/deltacontrols.nl\/fr\/wp-json\/wp\/v2\/project\/251574\/revisions\/251656"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/deltacontrols.nl\/fr\/wp-json\/wp\/v2\/media\/251575"}],"wp:attachment":[{"href":"https:\/\/deltacontrols.nl\/fr\/wp-json\/wp\/v2\/media?parent=251574"}],"wp:term":[{"taxonomy":"project_category","embeddable":true,"href":"https:\/\/deltacontrols.nl\/fr\/wp-json\/wp\/v2\/project_category?post=251574"},{"taxonomy":"project_tag","embeddable":true,"href":"https:\/\/deltacontrols.nl\/fr\/wp-json\/wp\/v2\/project_tag?post=251574"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}